Leading Manufacturers, Exporters, Wholesaler, Trader and Distributor of ECG 300 Electrocardiograph Machine and ECG 1201 Electrocardiograph Machine from Nashik.

Business Type Importer
Type Ecg Machine
Application Medical Use
Voltage 110V
Power 1000-1500 W
Driven Type Electric
Automation Grade Automatic

Preferred Buyer From

Location Anywhere in India

Product Description

  • AC / DC Operated
  • 3 channel ECG with data Interpretation
  • Rechargeable Lithium Battery
  • Battery Backup: 90 minutes (with continuous printing)
  • Simultaneous display of 3/6/12 leads ECG waveform, and can
  • remark the lead sign, sensitivity paper speed and filter state
  • Memory: 150 pieces of ECG waveform and works 90 mins
  • continuous after full battery charge
  • Storage : 1000 cases
  • It can store more than 1000 patient’s data (cases),
  • more convenient for data review & statistics
  • Portable, Light weight and sturdy look
  • Mode of printing: Automatic/Manual


Technical Specifications:

  • 3.5″Color LCD [Touch Screen Optional]
  • Power Supply
  •         AC: 110 ~ 240V, 50/60 Hz
  •         DC: 7.4V, 3700 mAh rechargeable lithium battery
  • Input way : Floating and defibrillation protection
  • Lead : 12 leads
  • Patient leak current : ≤10μA
  • Frequency response : 0.05Hz ~ 150Hz [-3dB ~ 0.4dB]
  • Time Constant : Time ≥ 3.2s
  • CMRR : ≥ 60dB, ≥ 100dB[Add filter]
  • EMG interference filter : 35Hz[-3dB]
  • AC Filter : 50/60 Hz
  • Sampling rate : 1000 Hz
  • Recording way :Thermal printing system [32 spots/mm]
  • Specification of recording paper: 80mm [W] X20m [L]


Measurement parameter:

  • HR, P-R interval P Duration, QRS Duration, Q Interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5) + S(V1)


High speed thermal paper :
Paper speed:

  •     Auto Record : 25mm/s, 50mm/s
  •     Manual Record : 5, 10, 25, 50mm/s
  •     Rhythm Record : 25mm/s, 50mm/s
  • Sensitivity choice : 5, 10, 20 mm/mV; Error: ≥15%
  • Standard sensitivity is 10 mm/mV : 0.2 mm/mV
  • Classification : Class I, CF applied part
  • Enduring polarization voltage : ≥1500 mV
  • Fuse Specification : 2pcs [5*20mm AC time lags]; T1.6AL250V [Power Supply: 220V]
  • Machine Size : 315(L)X 215(W) X 77(H) mm
  • Net Weight : 1.7 Kg
  • Auto Interpretation

 

  • Printing Modes:
  • 4*3,
  • Auto 3*4 +1,
  • Auto 3*4,
  • Auto 2*6 +1,
  • Auto 2*6,
  • Auto3-2+1,
  • Auto3-2,
  • Rhythm 4,
  • Rhythm 3,
  • Rhythm 2 And
  • Manual mode.     Optional : Touch Screen and Software for Interface

 

Read More...


Yes! I am interested


ECG 1201 Electrocardiograph Machine

1 Peice (MOQ)

Get Best Price
Business Type Distributor
Type Ecg Machine
Application Medical Use
Voltage 220V
Driven Type Electric
Automation Grade Automatic
Frequency Response 0.05 ~ 150Hz [-3dB ~ 0.4dB]
Lead Standard 12 leads

Preferred Buyer From

Location Anywhere in India

Product Description

  • 8″ LCD display with Touch screen
  • Power Supply:

         AC 100 ~ 240V, 50/60Hz

        DC 14.8V, 3700mAh rechargeable lithium battery

  • Input way: Floating and Defibrillation Protection
  • Lead: Standard 12 leads
  • Patient leak current : ≤ 10μA
  • Input Impedance : ≥50MΩ
  • Frequency Response : 0.05 ~ 150Hz [-3dB ~ 0.4dB]
  • Time Constant : Time ≥3.2s
  • CMRR : ≥ 60dB, ≥100dB [Add Filter]
  • EMG Interference Filter : 35Hz [-3dB]
  • Recording way : Thermal Printing System
  • Recording: Auto, Manual and Rhythm
  • Paper Size: 210mm [W] x 20m [L] high speed thermal paper
  • Paper Speed:
  • Auto Record: 25mm/s, 50mm/s, error ±5% [Record setup according to auto record format and mode,
    automatically changing leads, measuring and analyzing]
  • Rhythm Record: 25mm/s, 50mm/s, error ±5% [Record setup according to auto record format and mode, automatically measuring and analyzing]
  • Manual Record: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error ±5%

[Record setup according to auto record format and mode, manual changing leads]

  • Sensitivity Selection : 5, 10, 20, 40 mm/mV, [Error ±5%]
  • Standard sensitivity is 10mm/mV ±0.2mm/mV
  • Printing Modes:
  • 12*1,
  • 6*2 + 1,
  • 6*2,

 

  • Measurement parameters :     HR, P-R interval P duration, QRS duration, T duration, Q-T  interval, Q-Tc, P Axis, QRS Axis, T Axis, R[V5], S[V1], R[V5]+S[V1]

 

  • Product Safety Type: Class I CF applied part, there is defibrillation and pacing protection circuit in it
  • Ending Polarization voltage: ±5OOmV
  • Noise Level: ≤15μVp-p
  • Machine Size: 334mm[L] X 320mm[W] X 85mm[H]
  • Machine Net Weight: 2.25Kg
  • OPTIONAL: Communicate with PC via RS 232 interface and Software

 